Category: Read Locked MCU Data

  • R5F35L30KFF: The 125°C Grade Of A 64 KB M16C/5L

    Ordering the R5F35L30KFF instead of the J-grade part buys a temperature rating, not a different chip. Both carry 64 KB of program ROM 1, 4 KB of RAM and the same 64-pin LQFP, but the K suffix qualifies the die from minus 40 to plus 125 degrees Celsius. On an engine-bay controller that difference decides whether the unit is still in service at all. The R5F35L36JFF extraction note covers the 128 KB sibling with the same rating ladder.

    A Grade, Not A Second Mask

    Renesas sorted these grades by testing, so the mask set, the memory map and the protection registers are identical. That is good news for recovery: a procedure validated on a J-grade sample transfers without change. It also means the memory type comparison applies directly, and the 26DFE sibling page documents how the same 8 KB data flash behaves on a low-voltage member. What changes on the bench is supply margin, because a part rated for 125 degrees has usually spent years at elevated temperature and its charge retention deserves a second read.

    Reading Order On Aged Silicon

    Thermal history shows up as weak cells rather than as a dead chip. A long-lived K-grade device may return a clean first pass and disagree on one byte at the second, which is why two reads at a steady rail are part of the routine rather than an optional check. For contrast, an AVR fuse-bit case shows a family where the protection state is a handful of configuration bits; on M16C the equivalent is a word at the top of the array plus a protect bit in the flash control register.

    Two Gates, Neither Destructive

    A refused session is the worst outcome of a wrong ID on the 30KFF, and that is worth stating plainly. The comparison reads the upper option bytes, the protect setting gates the on-board programmer, and neither action triggers an erase. Unlike a fuse, both can be reprogrammed. So the high-temperature grade keeps its contents through any number of failed connections, which is exactly what a physical capture depends on.

    Start from F0000h and read upward: 64 KB of code ends at FFFFFh, where the vectors and the ID bytes also live. Down at 10000h a fixed 16 KB monitor block is present on every group member. The 8 KB data area is split into 4 KB halves between 0E000h and 0FFFFh. Only 4 KB of RAM exists, addressed 00400h to 013FFh, so the heat grade changes no boundary at all.

    The Map Is Shared

    A steady 5.0 V rail is held throughout both passes on this K-grade sample, because sweeping the supply mid-capture would hide the weak cells we are looking for. Code is read first, then the monitor area, then each data sector, then options. Cycling limits are 1,000 for the program arrays and 10,000 for data storage. The report states whether the two passes agreed on every byte.

    The customer receives a merged HEX plus separate binaries, and a note that records the ID and two option bytes, the state of both data sectors, checksums for each region, the capture rail and the outcome of the comparison pass. For a graded part we also state whether a third read was needed. Variable names and comments cannot be reconstructed from the array.

    Reporting And Hand-Off

    The 32 MHz clock comes from the main oscillator, a sub-clock, or either of two on-chip oscillators, with a PLL available when the application needs full speed.

    A watchdog with its own 125 kHz oscillator, a real-time clock, low-voltage detection and power-on reset all remain active at the high-temperature grade.

    Nine 16-bit multifunction timer channels plus a 16-bit input-capture and output-compare timer serve the motor and capture functions on this group.

    Thermal cycling also stresses the solder joints around the 64-lead body, so a board that fails to boot may simply need reflowing before any readout is attempted.

    A K-grade controller should travel unpowered and static-safe, with any thermal history written on the note. If the ID gate will not open, the contact form books the die-level work and the verified dump that follows. That history is not paperwork for its own sake: it tells us whether to plan a third confirming read before releasing the file.

    Service scope and next steps

    For Renesas targets we identify the device and check the read protection setting up front, then confirm which memory regions are reachable. The full scope of what we handle, how a project runs from electrical integrity test to delivered file, and the payment terms are described on our service capabilities page.

    Ready to extract this Renesas image?

    Send us the part number and a short description of what you need. Free evaluation, fixed quotation, and a reply within one business day.

    Request a quotation

  • STM32H7 (Cortex-M7) Microcontroller Family – Flash Readout, Code Extraction & Clone

    The STM32H7 (Cortex-M7) is STMicroelectronics’s 32-bit ARM Cortex-M7 (M4 co-proc). STM32H7 is ST’s highest-performance Cortex-M family, running a 400-480 MHz dual-core (M7 + M4) pipeline with up to 2 MB of Flash and over 1 MB of SRAM for graphics, AI and real-time control.

    STM32H7 (Cortex-M7) Sub-Families & Key Variants

    Sub-family / variant Memory & clock Highlights
    STM32H743 / 753 480 MHz M7, 2 MB Flash, 1 MB SRAM TFT, ETH, USB HS, DCMI
    STM32H745 / 747 Dual M7+M4, 2 MB Flash Asymmetric multi-core, TFT
    STM32H725 / 730 550 MHz M7, external-memory iface High-speed serial, FMC
    STM32H7B0 / 7A0 Value line, 280 MHz, 128 KB Flash Cost-sensitive H7, quad-SPI

    Readout Protection on STM32H7 (Cortex-M7)

    STM32H7 extends RDP Level 0/1/2 with WRP, PCROP, secure user memory, and on some parts a hardware secure boot and trust-zone style isolation, making unprotected extraction a real engineering task. For any locked STM32H7 (Cortex-M7) we start from the silicon, not the programming header, because the protection is designed to refuse a clean external read.

    Flash Extraction & Clone Workflow

    When a customer ships us a protected STM32H7 (Cortex-M7), the work usually follows the same path: identify the exact package and die, then carry out RDP Level-2 containment and external-memory-interface (FMC/quad-SPI) dump on the 743/745 die. We read the internal memory non-destructively where the protection allows, reconstruct the binary or hex image, verify it against a known-good checksum, and finally program a blank device or deliver the recovered firmware. Every step is documented so the result can be reproduced or re-used for production cloning.

    Applications We See

    human-machine interfaces, embedded AI inference, industrial communication, and high-end instruments. Our engineers routinely read out, recover and clone the full STM32H7 (Cortex-M7) range – from the smallest derivatives to the high-pin-count members listed above.

    If you need a STM32H7 (Cortex-M7) read out, cloned or recovered, use our MCU code extraction service · contact our engineers · related STM32 family page · related STM32 family page · related STM32 family page. We handle locked, encrypted and OTP parts across all major vendors.

    Service scope and next steps

    For STM32 targets the readout protection level decides the approach, so we verify the option bytes and the exact part number first. That keeps the quotation accurate and the timeline predictable. The full scope of what we handle, how a project runs from electrical integrity test to delivered file, and the payment terms are described on our service capabilities page.

    Ready to extract this STM32 image?

    Send us the part number and a short description of what you need. Free evaluation, fixed quotation, and a reply within one business day.

    Request a quotation

  • STM32H743AII6TR: Reeled Variant Of A 2 MB Graphics Part

    Rather than a new device, the STM32H743AII6TR is simply the AII6 ordered on a reel. Inside the UFBGA169 lid there is a 480 MHz M7, 2 MB of flash arranged as two banks, a full megabyte of system RAM, and the LTDC/DMA2D/JPEG graphics chain. TR is an ordering suffix describing the carrier, not a second mask set: the die, its protection map and the readout procedure match the tray part exactly. High-volume lines prefer reels because feeders sustain placement throughput that trays cannot, whereas a prototype bench build usually orders the bare code; neither choice reaches the silicon. The bypass-protection overview explains why the ordering code never alters the lock behaviour. A locked STM32H743AII6 read covers the tray-form counterpart, which shares the map exactly.

    Reel Code On A Panel Part

    A copy of a secured STM32H730IBK6Q shows a no-external-memory H7 cousin carrying the same lock word, a useful reminder that the carrier never reaches the debug port. For a very different architecture, copying an STM32F103 firmware shows the classic Cortex-M3 baseline that many engineers still cut their teeth on. Because the part has graphics, the 1 MB of SRAM holds framebuffers the LTDC drives directly, so the recovery must capture the display registers as well as the code. The ordering code is a logistics tag that the silicon never sees, so it has no bearing on how the array is read or what the lock permits, and the bench treats the two carriers as one.

    Test Budget Pressures

    Volume builds that use the TR code tend to be the ones with the tightest test budgets, and that is exactly where a wrong assumption about the lock bites. A contract manufacturer may set RDP level 1 on the line to discourage field cloning, then discover during rework that the firmware cannot be read back for a legitimate fix. Knowing that the TR suffix carries no extra protection lets the test engineer plan a recovery path the production team did not anticipate, using the same bench procedure as the tray part. The reel is a packaging choice decided at the back end of the line, far from the protection logic that was set at programming time, so the two never interact.

    Protection Is Identical

    The reel suffix does not touch the lock, which is one option byte. 0xAA leaves the chip readable, 0xBB engages level 1; 0xCC is the permanent level 2. The byte is written to FLASH_OPTSR_PRG and locked with OPTSTART, becoming active once the option page reloads after a reset. At level 1 the array, its backup register file and backup SRAM vanish from the probe, and the 1 MB RAM is sealed once reset completes, so the ordering code never alters lock behaviour.

    PCROP is programmed in FLASH_PRAR_PRG at a 256-byte alignment, so only instruction fetches reach the region while data traffic, DMA and debug get nothing. FLASH_WPSN holds the per-sector lock.

    Sixteen Sectors Again

    A sixteen-sector 2 MB map over two banks of eight makes the array, and SWAP_BANK_OPT can remap the halves. The reel the part ships on does not touch this layout at all. As with the tray part, the 1 MB SRAM holds the framebuffers the LTDC uses, so the capture must include the display and DMA2D registers, and the reader must first establish the running half before any vector address is credible. Graphics plus a two-bank array is the richest case in the H743 family.

    Bank Sectors Typical content
    0 0 to 7 active application
    1 8 to 15 staged update

    The option byte comes before the flash. Confirm the initial vector matches the density code, note the RDP level, the execute-only region and the WRP mask, then capture the sixteen sectors.

    Two passes at the same supply make ECC errors visible in FLASH_ECCR rather than in the data. The core’s own LDO that supplies the 1.2 V core dislikes noise, so a clean VCAP is what keeps the capture free of spurious faults.

    Tray And Reel Alike

    Closed ports are handled by the extraction service for the package and board steps. The reel origin changes nothing about the read: a UFBGA169 is reflowed and reballed after the lid is off, and the two-bank dump with the display registers captured is the same job as the tray part. Treat TR as a logistics tag, not a technical variable.

    Service scope and next steps

    For STM32 targets the readout protection level decides the approach, so we verify the option bytes and the exact part number first. That keeps the quotation accurate and the timeline predictable. The full scope of what we handle, how a project runs from electrical integrity test to delivered file, and the payment terms are described on our service capabilities page.

    Ready to extract this STM32 image?

    Send us the part number and a short description of what you need. Free evaluation, fixed quotation, and a reply within one business day.

    Request a quotation

  • STM32H742VIH6: Two Megabytes Under A 100-Ball Lid

    A 2 MB array under a hundred-ball lid is a rare combination, and the STM32H742VIH6 is exactly that: a 480 MHz Cortex-M7 holding a 2 MB array in two banks and 692 KB of SRAM in a TFBGA100, the smallest ball-grid body that still carries the full H742 memory. Like every H742 it omits the LTDC and the JPEG engine, so the graphics pipeline is absent while the protection logic stays standard. The density is what makes the VIH6 attractive for data-heavy logging or web-adjacent firmware where a smaller H7 would run out of room. The otp-versus-flash reference is worth reading here because the part mixes user flash, option bytes and backup registers, and knowing which domain holds a secret changes the read order. A locked STM32H742VGT6 read covers the 1 MB LQFP twin with the same lock map and the same word.

    Density In A Small Body

    Packing 2 MB into 100 balls means the external interface is thinner than on the larger parts, but the internal map is the same dual-bank structure as its siblings. A recovery that assumes a single bank will misplace the reset vector, because the SWAP_BANK_OPT bit can silently remap the two halves between resets. A restored STM32H725RGV6 program follows the same level scheme on a 550 MHz sibling that does carry crypto, which proves the lock levels travel unchanged across the family. With no cryptographic accelerator on the VIH6 there is no Secure Firmware Install region to hunt for, so the flash is the whole target and the capture is simpler than on a crypto part. For the older-core equivalent, decrypting an STM32F205 array shows a similar idea on a Cortex-M3 device.

    Two Banks, One Vector

    The bank layout is the one trap on a 2 MB part. Eight sectors per bank means the live firmware could be in either half, and a board that updated in the field may have flipped SWAP_BANK_OPT without leaving any other trace. Reading both banks and comparing them against the density code is not optional; it is the only way to know which image is current. Teams that dump a single bank and ship it often discover the clone boots into the bootloader and stops, because they captured the stale half. A two-bank read takes minutes longer and prevents a failed recovery, and it also reveals whether the device was ever reflashed in the field.

    Protection Byte Explained

    One byte decides whether the probe can read the part. 0xAA means unlocked, 0xBB is the standard level 1; 0xCC, by contrast, fuses the debug path permanently. That byte is programmed through FLASH_OPTSR_PRG and latched with OPTSTART, and the new state appears only after a reset has reloaded the option block. At level 1 the probe loses the array, the backup registers and the backup SRAM, and the H7 family seals on-chip RAM after each reset as well, defeating a staging trick that older cores allowed.

    PCROP is set in FLASH_PRAR_PRG, aligned to 256 bytes, which means only code fetches get through; plain reads, DMA transfers and debug taps all return nothing. The write lock for each sector lives in FLASH_WPSN.

    Sector Layout At Two Megabytes

    Sixteen sectors of 128 KB each fill the 2 MB array, split evenly between two banks, and SWAP_BANK_OPT can remap them. The thin TFBGA100 interface hides none of this, but the reader still has to determine the active half before the reset vector means anything. SRAM totals 692 KB here, partitioned into tightly coupled blocks and ordinary system memory, the whole of it sealed at level 1 on a locked device. Derive the PCROP and bank edges from the actual density code rather than guessing, or the boot vector lands in the wrong half and the clone never starts.

    Start with the option byte, not the array. Record the readout level, the PCROP area and the WRP mask, then dump the full sixteen sectors.

    Reading the array twice at the same supply lets ECC errors report via FLASH_ECCR rather than damage the data. A clean 1.2 V supply from the internal LDO keeps ECC quiet, so bench supply and VCAP decoupling decide read quality.

    Bench Steps For The VIH6

    Once the debug interface is shut, the contact channel handles the board and chip work without a bench. A TFBGA100 is reflowed rather than lifted, so the read happens after the lid is removed and the die is presented to the socket. The two-bank layout is the only subtlety; with the running half identified, the sixteen-sector dump is unremarkable.

    Service scope and next steps

    For STM32 targets the readout protection level decides the approach, so we verify the option bytes and the exact part number first. That keeps the quotation accurate and the timeline predictable. The full scope of what we handle, how a project runs from electrical integrity test to delivered file, and the payment terms are described on our service capabilities page.

    Ready to extract this STM32 image?

    Send us the part number and a short description of what you need. Free evaluation, fixed quotation, and a reply within one business day.

    Request a quotation

  • STM32H753XIH6TR: The Reeled Form Of A Crypto Part

    Ordering the STM32H753XIH6 on a reel changes the label, not the chip. The reeled code still denotes a 480 MHz Cortex-M7 with 2 MB of flash in two banks, 1 MB of SRAM and a 265-ball TFBGA body, plus AES, SHA, a TRNG and the secure-install path. The suffix records the factory carrier used by automated placement lines, so neither the die nor its protection map nor the recovery method differs from the tray version. Feeder-fed assembly simply keeps pace with volume builds in a way that manual tray loading does not. Depending on the design, a key may sit in the user array, the option-byte page or a dedicated crypto register, which is why the nvram extraction note is worth reading. An encrypted STM32H753XIH6 read documents the tray-code sibling and the same AES hardware.

    Label Change Only

    A recovered STM32H7B0ZBT6 source shows an H7 relative that keeps all code on chip yet shares the same lock byte, evidence that protection is family property rather than a packaging option. On a much older bus architecture, extracting an LPC2468 image shows an older ARM7 part with its own lock story and no crypto at all. Crypto hardware means the SFI staging area may carry its own write lock, and a complete archive therefore holds the plaintext program plus the encrypted update blob. Nothing in the carrier reaches the die, so the tray and reel parts are handled by one bench procedure and treated by the lock as a single device.

    Traceability Records

    Production traceability is the only thing the TR suffix genuinely affects, and it is worth recording alongside the firmware. A reel carries a lot code and a date that the tray part may not, and when a recovery is done to investigate a field failure those details can point at a specific wafer lot. The firmware image itself is identical, but the context that explains why a part failed often lives in the logistics record. Keeping the TR suffix and lot code with the dump turns a code recovery into a usable failure report, which is far more valuable to a quality team than the binary alone, and it closes the loop between the reel and the return.

    Lock Logic Unaltered

    The reeled crypto part keeps the same lock byte as the tray version; the silicon is one die. 0xAA leaves it open, 0xBB applies level 1 and 0xCC is the permanent level 2. Programming writes FLASH_OPTSR_PRG and sets OPTSTART, applying after the option block reloads on the next reset. With level 1 engaged the probe cannot reach the flash, backup SRAM or backup registers, and RAM stays frozen after reset, so the ordering suffix leaves the procedure exactly as it was and key registers still come from the array.

    The execute-only span goes in FLASH_PRAR_PRG, aligned to 256 bytes, and instruction fetches alone reach it; read traffic, DMA and the debugger all return nothing. FLASH_WPSN stores the per-sector lock.

    Bank Order On The Bench

    Eight sectors per bank, sixteen in total and each 128 KB wide, with SWAP_BANK_OPT free to exchange them; the carrier code has no effect here. Key material sits in registers beyond the user array, so those registers join the flash dump. Bench order is fixed: identify the running bank, check the start address against the density marking, then read both halves together with the crypto setup. Under the mould compound the 265-ball package is the same for reeled and tray parts.

    Layer Register Effect
    Readout FLASH_OPTSR_PRG debug port gated
    Execute-only FLASH_PRAR_PRG data reads refused
    Write lock FLASH_WPSN sector erase denied

    Pull the lock byte ahead of the flash. Check the boot vector against the package density, record the lock level, the proprietary span and the sector write table, then capture every 128 KB block.

    Two passes at a steady rail let ECC faults show in FLASH_ECCR instead of in the bytes. The low-dropout regulator that drives the 1.2 V domain reacts to noise, so the reeled part needs the same quiet VCAP bypass network as any other.

    One Verified Image

    A closed port simply routes the job to the contact channel, which returns one verified image for both TR and non-TR parts. Reflowing the 265-ball body and quieting the VCAP network come first; then both banks are read together with the crypto setup in one pass, exactly as for the tray order code. Nothing about the carrier changes that sequence, and the suffix belongs in the paperwork rather than the read plan.

    Service scope and next steps

    For STM32 targets the readout protection level decides the approach, so we verify the option bytes and the exact part number first. That keeps the quotation accurate and the timeline predictable. The full scope of what we handle, how a project runs from electrical integrity test to delivered file, and the payment terms are described on our service capabilities page.

    Ready to extract this STM32 image?

    Send us the part number and a short description of what you need. Free evaluation, fixed quotation, and a reply within one business day.

    Request a quotation

  • STM32H747IGT6: Two Cores, Crypto Present, One Debug Port

    The STM32H747IGT6 is the part where the H7 line gets interesting: not one but two cores — a Cortex-M7 at 480 MHz paired with a Cortex-M4 at 240 MHz — sharing a 1 MB flash in an LQFP176, and unlike the plain H743 it finally adds a cryptographic accelerator with AES, SHA and a hardware TRNG. The debug surface is one physical SWD/JTAG port for both cores, which matters a great deal when the protection word is set. Both processors boot from the same flash and share the SRAM and peripherals through a bus matrix, so a lock has to cover both. The bypass-protection overview frames why a shared debug port changes the recovery choreography rather than the lock levels. A secured STM32H753XIH6 read covers the crypto single-core cousin with the same AES block.

    Two Cores Behind One Port

    Because the part has crypto, there is also a Secure Firmware Install path, so a wrapped image may sit beside the application code and must be captured as well. A read-protected STM32H745IGT6 reference covers the dual-core crypto twin in LQFP176 as well, which is useful when the two cores split a crypto task from the main loop. For a different vendor view, dumping a secured STM32F407 shows the older M4 ancestor of the execute-only window on a part with no second core at all. The shared port means a single lock word gates both processors, so neither core can stage a clone in volatile memory once level 1 is set, and the key registers are reached through the same debug path.

    Secure Install Stage

    Splitting work across two cores changes what a recovery must preserve. The M4 often owns the real-time or communications task while the M7 runs the main application, and the handover between them lives in shared memory and a handful of inter-core flags. A clone that only captures the M7 side will boot and then stall waiting for a message that never arrives, because the M4 firmware that should send it was not in the archive. Treating the part as a two-program system, not a single image, is the correction most teams need, and skipping the M4 side is the usual reason a dual-core recovery looks complete yet will not run. The inter-core mailbox registers are the missing piece.

    A Shared Lock Byte

    Two cores share one debug port, yet the read lock is still a single option byte. 0xAA opens it, 0xBB is level 1; 0xCC, by comparison, is the permanent level 2 that gates both processors together. Written into FLASH_OPTSR_PRG and committed by OPTSTART, it takes hold after the option bytes reload and a reset. Level 1 gates the flash, its two backup domains and the register file away from the probe, and the shared RAM on this H7 is frozen at reset, so neither core can stage a clone in volatile memory.

    The protected code area is configured in FLASH_PRAR_PRG on a 256-byte boundary; only instruction fetches pass, while loads through the data bus, DMA and debug all fail. Write locks per sector are in FLASH_WPSN.

    Single Bank Register Map

    The array is eight 128 KB sectors in a single bank, simpler than the 2 MB parts but still under the same RDP and PCROP words. Because the M4 can run a crypto or comms task while the M7 runs the main loop, the register set worth preserving spans both cores, not just the M7. The 1 MB of SRAM is shared through the bus matrix, and on a closed part all of it is sealed behind level 1 with the flash. The crypto key registers sit beside the user array and must travel with the dump.

    Start at the lock word; both banks follow. Capture the lock level together with the PCROP boundary and the sector write map, then copy all eight sectors.

    Because two cores share the flash, run the capture twice at a steady supply so ECC faults report through FLASH_ECCR rather than corrupting bytes. The 1.2 V domain from the on-die LDO is noise-sensitive, so the VCAP bypass network must be quiet before the read starts.

    Preserving The M4 Side

    When the debug port will not open, the contact channel handles the package and die work on site. The LQFP176 is leaded and therefore reachable without a reball, and the eight-sector dump with the crypto key registers and both cores’ state captured is a standard job once the lock word is read. The dual core adds register breadth, not lock difficulty.

    Service scope and next steps

    For STM32 targets the readout protection level decides the approach, so we verify the option bytes and the exact part number first. That keeps the quotation accurate and the timeline predictable. The full scope of what we handle, how a project runs from electrical integrity test to delivered file, and the payment terms are described on our service capabilities page.

    Ready to extract this STM32 image?

    Send us the part number and a short description of what you need. Free evaluation, fixed quotation, and a reply within one business day.

    Request a quotation

  • STM32H742VGT6: The LQFP100 Twin Of The VGH6

    A leaded LQFP is far friendlier than a ball grid when the debug port is closed and the package has to come off, which is exactly why the STM32H742VGT6 exists: a 480 MHz M7 core with a single-bank 1 MB flash and 692 KB of SRAM in an LQFP100, the same headless H742 feature set as the VGH6 but in a package you can lift with hot air instead of a reball. The pins are visible and reballing is simply not part of the job, which is why the VGT6 shows up in lower-volume and prototype hardware. A locked STM32H742VIH6 is the same core with a 2 MB array in TFBGA100, so the package is the main practical difference and the readout logic is shared. The bypass-protection overview explains why these mechanisms behave the way they do across the STM32 range.

    Leaded Over Ball Grid

    The single biggest practical difference from a BGA sibling is reachability. When the debug port is closed on a TFBGA part, the lid usually has to come off, which means hot-air rework, a stencil and a reball — slow, and risky on a 0.8 mm pitch grid. On the LQFP100 the part can be lifted with a standard hot-air tool, dropped into a test socket, or even read in place with a clamp on the exposed leads, so a closed port is far less of a barrier. A locked STM32H723ZEI6 read follows the same option-byte logic on a 550 MHz core with a smaller array, and the steps transfer cleanly. For the older-core version of the same procedure, a locked STM32F405 read shows how the execute-only window looked before dual-bank flash existed.

    Reachability On The Bench

    Reading in place with a lead clamp is the option that saves the board. Many service jobs are on a device that must go back into the field, and lifting the package is a last resort. With the LQFP100 the clamp makes contact on the exposed pins while the part stays soldered, so the firmware comes off without the risk of damaging the pads or the surrounding components. The trade is signal integrity: a clamp read needs a clean supply and patience, because a poor contact looks exactly like a protection fault and can send the recovery down the wrong path for an afternoon. A stable bench supply and a fresh clamp tip turn that risk into a routine operation.

    In-Place Clamp Reads

    Guarding the firmware is one option byte. 0xAA keeps it readable, 0xBB switches on level 1; 0xCC instead closes level 2 with no undo. It is stored in FLASH_OPTSR_PRG and applied via the OPTSTART bit, with the change visible once the part reboots and the lock page reloads. Under level 1 the flash plus the backup SRAM and backup registers are absent from any probe, and system RAM here is frozen at reset, which is exactly why an in-place dump cannot be staged from running memory.

    The execute-only region comes from FLASH_PRAR_PRG, 256-byte aligned, and write locking works on a per-128-KB-sector basis via FLASH_WPSN.

    Eight Sectors, One Bank

    Eight 128 KB sectors form the array, and with no second bank the reset vector is set purely by the density code. A closed port changes nothing about the count; it only changes how the die is reached. There is no display framebuffer and no Chrom-ART DMA2D to model, which keeps the register set small, and the 692 KB SRAM pool is part TCM and part ordinary memory, all of it behind the same level 1 gate as the flash. The leaded body is the feature that makes the whole job tractable without a rework station.

    Read the option-byte word before anything else. Grab the protection level, the PCROP boundary and the write-protection table, then dump the eight sectors.

    ECC faults are reported by FLASH_ECCR and never silently corrupt the data. The 1.2 V domain supplied by the on-die regulator is sensitive to supply noise, so a stable VCAP is part of the bench plan.

    Service And Repair Work

    If the port will not open, the contact channel does the package and substrate recovery. The leaded body means a socket or in-place clamp read is practical without removing the part, and the eight-sector dump with the option bytes captured first is a routine capture. That is why this variant turns up in service, repair and low-volume hardware where someone may need to read a part that is already soldered down.

    Service scope and next steps

    For STM32 targets the readout protection level decides the approach, so we verify the option bytes and the exact part number first. That keeps the quotation accurate and the timeline predictable. The full scope of what we handle, how a project runs from electrical integrity test to delivered file, and the payment terms are described on our service capabilities page.

    Ready to extract this STM32 image?

    Send us the part number and a short description of what you need. Free evaluation, fixed quotation, and a reply within one business day.

    Request a quotation

  • STM32H742VGT6TR: Same Die, Reeled For Automated Placement

    The STM32H742VGT6TR is the VGT6 in tape-and-reel packaging: the same M7 silicon at 480 MHz, the same single-bank 1 MB flash, the same 692 KB of SRAM in LQFP100, and the same headless feature set without LTDC or JPEG. The only difference the TR suffix marks is how the parts leave the factory — on a reel for automated pick-and-place rather than in a tray — and that changes nothing about the die or the protection map. The otp-versus-flash reference matters here when a design keeps its secret in user flash rather than option bytes, since the read order depends on the domain. A locked STM32H742VGT6 read covers the tray-form counterpart; its lock map and its eight-sector read are unchanged.

    Carrier, Not Silicon

    Automated lines standardise on tape-and-reel because feeders load faster and place more reliably than hand trays at volume, so a production BOM carries the TR code while a prototype build may use the bare code. The recovered firmware is byte-for-byte identical either way, because the silicon matches. An opened STM32H750IBT6 read shows a single-bank H7 cousin with the same word, proving the reel-origin part behaves no differently once it is on the bench. For a different architecture, extracting an AT32F405 firmware shows the Artery equivalent of this window on a competing Cortex-M4. Procurement teams should record the TR suffix for volume builds and the bare code for bench work, but the recovery workflow is identical.

    BOM Codes Compared

    The reel origin matters to logistics, not to silicon. A reel of parts and a tray of parts came off the same wafer lot with the same mask revision, so any drift between them would be a manufacturing defect rather than a design choice. When a recovered image from a reeled part is compared against one from a tray part, the only differences worth noting are the lot traceability fields, never the firmware or the lock state. Treating TR as a supply-chain attribute keeps the engineering record clean and stops teams from chasing a phantom behavioural difference that the reel can never introduce. The board it lands on is where the real variability lives.

    Lock Byte Unchanged

    The reeled variant carries the same lock as the tray part because the die is identical. A single option byte holds it: 0xAA open, 0xBB for level 1, 0xCC for the irreversible level 2. Programming writes FLASH_OPTSR_PRG and latches OPTSTART, and the setting sticks after the option block has reloaded on the next reset. With level 1 the array, backup registers and backup SRAM leave the debug view and the H7 seals RAM after reset, so the reel suffix changes nothing about how the recovery is scoped.

    Set the PCROP window in FLASH_PRAR_PRG, aligned to 256 bytes, and only code fetches are allowed; ordinary data fetches, DMA and the probe are all refused. The sector write lock is in FLASH_WPSN.

    Array Geometry Stays Put

    The array is eight 128 KB sectors with a single bank, so the reset vector follows the density code and the capture is one eight-sector pass. The reel packaging does not alter this at all. A headless part has no framebuffer and no Chrom-ART DMA2D to model, so the saved registers are limited to the clocks, GPIO and serial blocks, and SRAM is 692 KB split between a tightly coupled bank and the system area, hidden at level 1. From the reader’s bench the reel and the tray are the same component in a different carrier.

    Attribute Tray code TR code
    Carrier plastic tray tape and reel
    Placement manual or tube feeder
    Mask revision same wafer lot same wafer lot

    Take the option byte first and both banks afterwards. Pull the RDP setting, the code-readout window and the write lock bitmap, then copy all eight sectors.

    A double read at the same power state lets ECC faults show through FLASH_ECCR instead of corrupting bytes. The internal LDO that feeds the 1.2 V core is noise-sensitive, so decoupling around VCAP belongs in the bench setup from the start.

    Procurement Versus Recovery

    With the port shut, package and lid work belongs to the extraction service. The reel origin is invisible on the bench — the silicon matches — so the read is the standard eight-sector LQFP capture with the option bytes taken first. Treat the TR marking as a procurement detail, not a technical one.

    Service scope and next steps

    For STM32 targets the readout protection level decides the approach, so we verify the option bytes and the exact part number first. That keeps the quotation accurate and the timeline predictable. The full scope of what we handle, how a project runs from electrical integrity test to delivered file, and the payment terms are described on our service capabilities page.

    Ready to extract this STM32 image?

    Send us the part number and a short description of what you need. Free evaluation, fixed quotation, and a reply within one business day.

    Request a quotation